M302 p1. 0 F100 G90 reverse sends G91 G1 E-5. M302 p1

 
0 F100 G90 reverse sends G91 G1 E-5M302 p1 M302 P1 #Allow cold extrudes Reply ShadowRam Repstrap • Additional comment actions

Sevenfriday P2-2. P2- Tactical Handheld Radio. 1 Reply Last reply Reply Quote 0. Macros also allow for naming gcodes with easier to remember names. M302 P1. g macro is;Autoload filament macro. M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). M302 works fine in a starting script or sent via console. Firmware: Marlin 2. Preheat the hot end, if desired (or send M302 P1 if you intend to use the macro when the hot end is cold) Use M913 Ennn to reduce the motor current, if necessary (see #1 above) Use M83 to select relative extruder motion, in case the macro is. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Other possible causes are a bad stepper motor or cable. It can be caused. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. M302 Allow Cold Extrudes [Pnn/Snn/Rmm] Allow cold extrude, set min extrude & retract temps M302 P1 ; Allow cold extrusion M552 Set IP, enable/disable network in[Pnn / Snn/ Rnn] P(IPV4 address) S(0|1 enable|disable, M552 S1 P192. February 17, 2016 12:19PM Registered: 8 years ago Posts: 14,621 There is no minimum steps/mm set in the firmware. 7. Only users with topic management privileges can see it. . M563 P1 D1 G10 P1 S-273 R-273 X19. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPExtruding some filament with M302 P1 enabled (cold extrusion) with bowden out of hotend Extruding some filament with hotend at required temperature Printing a test print. I have a duet2 wifi that I'm working on. Yes. Command "M302 P1" works properly. When Cura calls "tool 0" or "tool 1" the printer executes "tfree1. They include all of the amenities you would expect in high-quality RVs, but they can make the RV dream a reality for individuals that are more budget-conscious. g: 1. I also want to be able to enter G-codes manually. . 155 5. Hi Saurabh, Here is M122: M302 P1. 1 Reply Last reply Reply Quote 0. Study with Quizlet and memorize flashcards containing terms like You have two buckets. When Cura calls "tool 0" or "tool 1" the printer executes "tfree1. E0 moved as expected Extrude sends G91 G1 E5. 4. 1 Reply Last reply Reply Quote 0. 2, Settings: FWRETRACT is not enabled, Slicer: Cura 4. Extrude a small amount to ensure that your extruder motor is on and holding. M302 P1. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion. M302 P1 ; allow cold extrusion. G54 Use workshift offset #1. The firmware normally prevents “cold extrudes”. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. @dc42 That doesn't seem to work. " So I attached a thermistor to the board just to "fool" the board int. Re-enable with. M302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears M109 S235 T0 ; set hotend temperature and wait G1 E200 F500 ; extrude 200mm, you may need to reduce speed for. 1 Reply Last reply Reply Quote 0. Hi, I've upgraded to firmware 3. (You'll. g. 3 ; Filter fan. 3. 3 ; Filter fan. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. P-Series P3C/07 Red Carbon NewAlso if you dont need a heated bed for whatever reason throw "m302 p1" into the beginning of the gcode Reply OGSniperKid •. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. Other possible causes are a bad stepper motor or cable. The extrude and retract buttons are grayed out when the thermistors aren't connected. 5 nH - 465 nH No. g file. Real retractions happens where they should and seems fine. Unmount the SD card and insert it into the Duet 2 Maestro board and power on. With M302 P1 command, if it works with my. Direct drive: Remove your nozzle, hotend, or extruder. 1 Reply Last reply Reply Quote 0. 0. 00 ; Disable bang-bang mode for the bed heater and set PWM limit M305 P0 T100000 B3950 ; Set thermistor + ADC parameters for heater 0 M143 H0 S120 ; Set temperature limit for heater 0 to 120C M305 P1 T100000 B3950 ; Set thermistor + ADC parameters for heater 1. This value gives better accuracy at typical printing temperatures in the range 190 to 250C than the B value of 4267 quoted in the datasheet. The extrude and retract buttons are grayed out when the thermistors aren't connected. A giveaway is that while it is buzzing you can turn the motor shaft by hand. the X motor connector. Ralms last edited by Ralms . my problem this Messege (Unknown command:“M302” )&(Move out of range: 37. 0. @zapta no i don't think M122 reports that but it will be reported in the console in normal use, unless M302 P1 is in use. Firmware: Marlin 2. Then reduce the distance, and stop just before the filament disappears into the hot end. M106 R2 ; restore print cooling fan speed M116 P1 ; wait for tool 1 heaters to reach operating temperature M83 ; relative extruder movement G1 E0. M302 P1 allows cold extrusion (RepRapFirmware). If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. Private Seller. the X motor connector. But only do that with the Bowden tube not connected to the hotend while calibrating! To reactivate cold extrusion checking you have to issue the command. 3, Speed 100% M106 P1 S0 I0 F4 H-1 L0. M302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. M307 H0 B0 S1. Step 3: Click on extensions, then click on modify G-Code. P1- Move under Direct Fire. zip. txt 📋 Copy to clipboard ⇓ Download M302 P1 Re-enable with disable-marlin-cold-extrusion-prevention-via-g-code. 0. M302 P1 ;allow cold extrusion T0 G1 E1000 F3600; Reply Quote. @dc42 That doesn't seem to work. 8. Can not get E0 to extrude, M302 P1 = still grey buttons2022-06-04 10:51:18 m302 Cold extrusion is allowed (use M302 P0 to forbid it) 2022-06-04 10:50:53 m302 p1 What is wrong when I get no control in DWC ? 3. g" or "tfree0. This macro correctly does the quick load and stall but then never continues to do the slow loading part (bolded) M400; Wait for current moves to finish M913 E50; reduce the motor current M83; relative extrude G91;. Extrude and retract a few times. 1. But the paste extruder is designed so that you can,. M302 P1 ;allow cold extrusion T0 G1 E1000 F3600 ;new step/mm = old*1000/Measured ;example 1024 measured with old steps = 310 -> new = 310*1000/1024 = 302. Now I can run the DC-encoder motor with M569 T3:3:3:3 timing. 3 Replies Last reply Reply Quote 0. 0 Firmware fully supporting this sensor: RRF and Klipper, Marlin very limited - not recommended. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. 155 5. e. 3 Replies Last reply 3 Dec 2020, 11:32 0. g. 2, Settings: FWRETRACT is not enabled, Slicer: Cura 4. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. Not sure what could be wrong in your case as M302 with no parameters should report the current cold extrusion protection settings. 3 I0 F500 H1 T45 ; Set fan 0 value, PWM signal. Report Save. 197 1. G4 S1 ; wait for one second. Here is my config. Solved; M302 P1 command I have a duet2 wifi that I'm working on. 7 F200 M118 S"Round 1" G4 P4000 G1 E7. The trigger2. M302 P1 ; enable cold extrusion. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. T0 selects tool 0 (Fisher has only one tool – its extruder drive plus its hot end – and T0 is it). org ]Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. When printing at 200 C, no problem, when printing at 180C or 190C, the printer does all the moves, but nothing extrudes, the extruder motor also doesnt move (I have a windmill attached to my motor). 7 F200 M118 S"Round 2" G4 P4000 G1 E7. 1M302 P1. To test for this, with the power off swap the E0 connector on the Duet with another one e. 00. g. Buzzing is normally because only one set of coils is being powered, so the motor just vibrates instead of turning. This tells the firmware to allow cold extrudes. 0beta4 (2021-09-27 11:30:36) Duet WiFi Server: 1. Configure the new steps/mm: M92 E391; Restart from step 3. what gcode do i need to send to tell it to ignore the fact the extruder temp is off and extrude for me so i can make sure the e motor works correctly before hooking the tube back up? 26 Dec 2022, 15:31 Duet 3 mini 5+ installed in a Sidewinder x1 v1. 0. 2. @GG said in Incredibly slow print speed: M203 X500. 4. 1 Reply Last reply Reply Quote 0. Trying to figure out why I can't run my extruder. Not sure what could be wrong in your case as M302 with no parameters should report the current cold extrusion protection settings. Trying to figure out why I can't run my extruder. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. B" i tried also P0" G92 E0 ; Reset. Printer::setColdExtrusionAllowed(!com->hasS() |. 0. zendesk. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. But it's a bit disapointing how raw the motor moves although there are 8344 QDE-pulses per turn of the output shaft. M302 P1 disables the cold extrude safety. i've sent M302 P1 and then G1 E2000 F1000 it worked. g file. (You will have to switch off the temperature control as most controllers will not move the extruder stepper unless the hot end it up to temperature) Use M302 P1 on RepRapFirmware to switch cold extrusion on (allow extrusion while cold) and M302 P0 to switch it off again. See config below. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. (You'll need to pull hard sometimes) Step 7 For maximum effectiveness you may need to repeat the process more than once. For firmware versions 1. Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. g M83 ; relative extruder movement G1 E-0. Code to reenable M302 P0. g sending e. (PREVENT_COLD_EXTRUSION) case 302: gcode_M302(); break; // M302: Set Minimum Extrusion Temp #endif *Edit: Added the. for cold extrusion you have to set M302 P1. The Matrice 30 series integrates multiple high-performance sensors into a lightweight and portable body. 2. RepRapFirmware. what gcode do i need to send to tell it to ignore the fact the extruder temp is off and extrude for me so i can make sure the e motor works correctly before hooking the tube back up?@Saurabh said in Duet 3 Extruder control disabled: Can you share output of M122 command and try cold extrude using M302 P1 it'll enable extrude button. The main features are: Filament Runout sensing Filament auto loading Button for filament unload Compatible with Orbiter v1. M302 P0 1. Trying to figure out why I can't run my extruder. But the extruder control section is still not active. Thermostatic control is turned off, Minimum fan value 0. shipping. Dwell/Exact stop. I cannot get the extruder controls to show up in the web interface - it is greyed out. 0. 01-RC9, DWC 2. Ok I will try the. S1 will disallow. droftarts administrators @flyscha last edited by . 1 Reply Last reply Reply Quote 0. Still no luck with Extrusion Control jogging buttons. T0 selects tool 0 (Fisher has only one tool – its extruder drive plus its hot end – and T0 is it). Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Still no luck with Extrusion Control jogging buttons. On my machine, the z-axis is adjusted manually and I would like to be able to programmatically turn on the laser with some minimum power for an indefinite time. Is it possible to measure and place exactly 4 gallons of water. 50 Caliber Machine Gun W5-MK 19 Heavy Grenade Launcher ESB 1: React to IED Attack ESB 2: Construct Individual Fighting Position Has M302 P1 which is used to allow cold extruding always required the heater to be active even though the temp settings (R/S) can be zero? Thanks. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Now advance the filament using the extrude button on the Machine Control tab, until it reaches the top of the heatsink. . I did hook it up to x axis physically and it worked. I preheat the hotend; Digi-Key: G4010L24B-RSR M106 P1 T45 S255 H1 ; HOTEND Fan Settings M950 F0 C"Fan0" Q25000 ; Creates PARTS COOLING FAN ; BLOWER 50X15MM 24VDC - 5. mp4. Ok I will try the bugfix branch with the config files you provided! Firmware: Marlin 2. @phaedrux I tried G1 E10 code and yes the extruder moved a bit. M563 P0 D0 H1 G10 P1 S0 R0 M563 P1 D2 H2 G10 P2 S0 R0 ; ;M92 E420:420 ; org extruder ratio M92 E420:97. Now I can run the DC-encoder motor with M569 T3:3:3:3 timing. com 6 Dec 2021, 06:22 @o_lampe - It seemed to be hit or miss in examples with the D0 in tool definition, so I left it out at first. M302 S100 would set the temp below your extrusion temperature. 동호회, 스터디, 주제별 모임을 밴드로 시작하세요. After creating these and making all the connections we can move onto updating the firmware. Mostly the layer height changes a little which you have to try a couple of times to see if the pressure is good enough for the filament to stick well to the fabric. g. 1 Reply Last reply Reply Quote 0. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Hello. Solved; M302 P1 command. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 26 Duet Web Control 3. Unfortunately, the. There no clog, I can extrude through octoprint, at 200C. Pianos; Keyboard Instruments; Guitars, Basses & AmpsH1 D0 ), it must be active (selected) and up to temperature (> 160C for extrusion AFAIR). DWC bug: extrusion controls kept inactive (grayed out) even if i enable cold extrusion by M302 P1. RepRapFirmware. M302 P1. However, some firmware distributions might explicitly prevent these two commands of turning off the check. Your config files updated for bugfix Configuration. Your tool definition misses a D parameter for the extruder drive. [Note: parameter letter E is a special case, an E parameter must always be preceded by a. 0. Cannot get extruder motor to respond. droftarts administrators @flyscha last edited by . Big Block Limited Edition $ 2,289. g. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. Macros also allow for naming gcodes with easier to remember names. Allow cold Filament Load/Unload with M302 P1 ; Level Corners with Probe option ; M808 Repeat Markers / "End Repeat Loops" menu item ; Make M220 B / R parameters standard ; Probe Tare, Probe Activation Switch (#20379, #20550) Laser Test Fire ;. 0C, min. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. M302 P1 Code to reenable M302 P0 You can also use it to change the minimum temp like this M302 S100 This will change the min temp to 100c. @carefullylarry said in Cannot reverse motor direction: Before trying to correct the stepper motor direction through the config file, I had tried switching the stepper motor wires and that partially worked. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. 0, v1. so i need to use cold extrusion So i used in my start machine setting in the slicer the following:; Ender 3 Custom Start G-code. 7 F200 M118 S"Round 3" G4 P4000 printed via DWC: Works fine: Video of executing that file: video_2021-01-28_15-52-49. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. [Note: parameter letter E is a special case, an E parameter must always be preceded by a. Send M302 on its own to check the state, post response from console. droftarts administrators @flyscha last edited by . Tools; M563 P1 S"Clay" D0 ; Define tool 1 M563 P2 S"plastic" D1 H2 ; Define tool 2 G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P2 X134 Y-18 Z0 ; Set tool 2 axis offsets M106 P0 S0. Step 6 Retract 150 mm of filament, then remove it from the filament drive. Here is my config. This remains in effect until the printer is shut off. 밴드는 그룹 멤버와 함께 하는 공간입니다. M302 P1 ;Disable extruder temp check G28 ;Home G92 E0 ;Reset Extruder G1 Z50 F3000 ;Move Z Axis up M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170. 16 and earlier, set the B parameter (beta value) to 4388. Both versions work on Duet 2. G10 P1 ; Set tool number 1 T0 ; Select tool 0 M302 P1 ; Allow cold extrusion. Set fan 0 value, PWM signal inversion and frequency. 0. A dialog stops at the relevant point, but prevents the G code input. (These won’t survive a power reset, so they’ll go back to normal at next startup; or you can use “M302 P0” or “M302 Sxxx”, where xxx is desired min extrusion temp, to reverse). You can delete this line once connected M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable Telnet ; Drives M569 P0 S0 ; Drive X M569 P1 S1 ; Drive Y M569 P2 S1 ; Drive Z1 M569 P3 S1 ; Drive E0 M569 P4 S1 ; Drive Z2 forwards M569 P5 S1 ;Drive PRINT-HEAD (E2) goes forwards M569 P6 S1 ; M569 P7 S1 ; M569. This is a prettified version of the Repetier-Firmware for AVR supported GCodes and MCodes as extracted from Repetier. 1 Reply Last reply Reply Quote 0. To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. 3. @carlosspr said in Filament loading with stall detection macro issue: maybe you need to enable cold extrusion with M302 P1 and afterwards disable with M302 P0 I don't want to do this cold. 7. Exponential interpolation, CCW (counterclockwise) G04. . M302 P1. If you create a tool with no heaters, extrusion does work using G1 E commands. 1 Reply Last reply Reply Quote 0. G43 Tool length compensation positive. 8. 2. ago I just found the problem and solution, actually. There are no markings on the buckets, and you are not able to mark the buckets in any way. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysM305 P1 T100000 B4725 C7. The macro folder can divided into sub directories to more easily organise your macros by type. 140m³/min) ; Digi-Key: B5015E24B-BSR M106 P0 H-1 ; Set fan 1 value, PWM signal inversion and frequency. Click to Enlarge. Thank you for your reply, but further confused. G57 Use workshift offset #4. g sending e. 1. When Cura calls "tool 0" or "tool 1" the printer executes "tfree1. 1 Reply Last reply. 3. g. So I have two tools set up on a duet 2 wifi. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). I have preheated the nozzle to 160 and also tried to issue a M302 P1 but that does not help either. @Phaedrux said in Extruder motor not working. Kits M302. M302 P1. 3 ; Cold-Section fan. So I have two tools set up on a duet 2 wifi. g sending e. 5 ; beltextruder ratio Reply Quote. Now advance the filament using the extrude button on the Machine Control tab, until it reaches the top of the heatsink. M302 P1. I assume that's my problem I just don't see. zfeng @Phaedrux last edited by . of Values: 98 (2 of each) Packaging: Acrylic Case; Mount: TH; Buy Now: Quantity . Run RESTART. Macros also allow for naming gcodes with easier to remember names. M302 P1. However, some firmware distributions might explicitly prevent these two commands. This topic has been deleted. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. The next time you turn it on it will be back at 175 degrees. 2, and M305. 1 Reply Last reply Reply Quote 0. Has M302 P1 which is used to allow cold extruding always required the heater to be active even though the temp settings (R/S) can be. ago Yeah figured out that after you pointed me to Github. Step 6. you are setting the speed to about 8mm/sec here. I have modified my printer to print clay. When I print using the code below (it is longer, but I do not know where to put attachments), I can see that the extruder-gear is jerking, as if it tries to do tiny retractions between every little movement. It worked:) Thanks for the help Real_Grapefruit91 • 8 mo. M302 7 mm and 10 mm Tunable Inductors. Set the temperature (and enable). droftarts administrators @flyscha last edited by . : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. As well as selecting the tool with e. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. if I check the status it shows that the E0 switch is triggered. 1. FrederickIf you would like it to be reactivated, please contact the site owner. ;. droftarts administrators @flyscha last edited by . This topic has been deleted. Here's the setup. EDIT: I see Gloomyandy got you there first. MC. contact us to reactivate your site. 43 M562 Reset Temperature Fault [Pnn] Reset temp fault on all heaters or on heater Pnn M562. ; Unload extruder 0 T-1 ; make sure all tools are deselected M302 P1 ; Allow cold extrusion ; todo free drive 0 M302 P0 ; Disable cold extrusion Now I know that I can allow cold extrusion with M302, but how would I actually move the E0 or E1 steppers?Hi, I a little confused, recently purchased Duet and Duex, plugged it in and checked device manager: COM 4 Due something, disconnect the Duet took out the SD card, modified it and checked it again and it worked, well, all apart from the extruders (with cold extrude enabled "m302 p1"). 5. With M302 P1 command, if it works with my config. 7 Move a motor on delta printer On delta printers, the X,Y and Z movements does not correspond to a motor movement, while for commissioning, you may want to operate each motor. If OK then disallow cold extrusion: M302 P0; Save new value: M500; 1. The commands I gave it was: T0 ; just to be sure M302 P1 ; I think it wPreheat the hot end, if desired (or send M302 P1 if you intend to use the macro when the hot end is cold) Use M913 Ennn to reduce the motor current, if necessary (see #1 above) Use M83 to select relative extruder motion, in case the macro is. To test for this, with the power off swap the E0 connector on the Duet with another one e. @c310 said in RRF 3. Some common uses… M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled How to disable Marlin cold extrusion prevention via G-Code If you want to test your extruder, you can disable cold extrusion prevention using M302: disable-marlin-cold-extrusion-prevention-via-g-code. The macro folder can divided into sub directories to more easily organise your macros by type. With M302 P1 command, if it works with my config. Other possible causes are a bad stepper motor or cable. It still stops randomly sometimes. dc42 administrators last edited by . Duet Web Control makes it easy to upload, edit and create new macros. Above floor (M302. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Life Technologies was acquired by Thermo Fisher Scientific in January, 2014. . droftarts administrators @flyscha last edited by . To test for this, with the power off swap the E0 connector on the Duet with another one e. Connector for the extruder is plugged into second connection (i. 0 ; Set microsteps per mm M204 P1000 T3000 ; Set printing and travel accelerations ; Original values ;M566 X600 Y600 Z100 E3000 ; Set maximum instantaneous speed changes (mm/min) (Jerk) ;M201 X300 Y300 Z30 E8000 ; Set maximum. @dc42 That doesn't seem to work. However, a steps/mm value of 5. 2 did not always return the complete list of access points found; M598 did not sync motion systems and only released axes owned by the currently-active motion systemSevenfriday P1-5. Mostly the layer height changes a little which you have to try a couple of times to see if the pressure is good enough for the filament to stick well to the fabric. Close Designer's Kit, Unicoil 7/10 mm inductors, RoHS Inductance Range: 44. 00 ; Disable bang-bang mode for the bed heater and set PWM limit M305 P0 T100000 B3950 ; Set thermistor + ADC parameters for heater 0 M143 H0 S120 ; Set temperature limit for heater 0 to 120C M305 P1 T100000 B3950 ; Set thermistor + ADC parameters for heater 1. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. 000 ) Describe your issue:. To test for this, with the power off swap the E0 connector on the Duet with another one e. Thermostatic control is turned off, Minimum fan value 0. · Issue #265 · Duet3D/DuetWebControl · GitHub The extrude and retract buttons are grayed out when the thermistors aren't connected. 1) 5. Duet software engineer. After sending M302 P1, try sending G1 E10 to see if the extruder will move. zip. M302 P1 ; enable cold extrusion. @o_lampe OK, I figured out I have to set the dir-interrupt to "CHANGE",. The labels makes it easier for me to get a feel for the group a specific command belongs to, and makes it easy to find commands related to some specific task. Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. 0 stable release but unfortunately with no effect. News Release; Products Information; JVC World Wide Web Site; Company ProfileT0 ; select extruder M302 P1 ; allow cold extrusion M92 X200. You are given a huge pool of water. 259 -49. Has M302 P1 which is used to allow cold extruding always required the heater to be active even though the temp settings (R/S) can be zero? Thanks. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. 2, Settings: FWRETRACT is not enabled, Slicer: Cura 4. The M302 P1 command overrides the normal prohibition on trying to extrude filament when the hot end is cold. Only users with topic management privileges can see it. A guide on how to install an E3D Chimera. M122 shows some weird messages: Driver 0: position 38683, standstill, read errors 0, write errors 1, ifcnt 23, reads 6775, writes 6, timeouts 0, DMA errors 0 Driver 1: position 38683, standstill, read errors 0, write errors 1, ifcnt 23. It worked:) Thanks for the help Real_Grapefruit91 • 8 mo. I'ved also tried the "M302 P1" to cold extrude but doesn't do anything, the buttons remain greyed out. The M302 P1 command overrides the normal prohibition on trying to extrude filament when the hot end is cold. 3. ) and overrides any similar commands earlier in config. 00 E830. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). G05. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPDuet Web Control makes it easy to upload, edit and create new macros. GG @Phaedrux last edited by @Phaedrux Duet2 ethernet purchased from Official reprap store thru aliexpress , July 2020, along with 4" paneldue. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. (You'll need to pull hard sometimes) Step 7 For maximum effectiveness you may need to repeat the process more than once. 7. If you want the extruder to move when cold, you can temporarily override with “M302 P1” or “M302 S0”. T0 selects tool 0 (Fisher has only one tool – its extruder drive plus its hot end – and T0 is it). M302 P1. Real_Grapefruit91 • 8 mo. maybe you need to enable cold extrusion with M302 P1 and afterwards disable with M302 P0In Part 1 of this two-part series, I covered the hardware changes needed to use Duet electronics with the Mini Kossel in place of Arduino/RAMPS electronics.